Specifications

6 7
WIRING TERMINAL
Wire specifications
18-24 gauge thermostat wire
Installation notes
Ensure power at the HVAC equipment is off.
Loosen screw terminals, insert stripped wire and
re-tighten.
Push the excess wire back into the opening and plug
the wall opening to prevent drafts.
INSTALLATION
RC24 VAC supply cooling*
R24 VAC supply heating*
W1st stage heat / auxiliary
Y1st stage cooling / compressor
G – Fan
CCommon (optional when powered by batteries)
S1 & S2 – outdoor temperature sensor (optional)
O/BReversing valve
L – System fault indicator
W22nd stage heat / auxiliary
Y22nd stage cooling / compressor
* Jumper between RC & R is used in single transformer systems
(see wiring diagrams).
C
G
Y
W
R
L
S1
S2
O/B
W2
Y2
RC
WIRING – SINGLE TRANSFORMER (USE
JUMPER WIRE) FOR HEAT/COOL SYSTEM
INSTALLATION
1st HEATING
1st COOLING
FAN
2nd HEATING
2nd COOLING
OUTDOOR TEMP
SENSOR
NOT USED
NOT USED
JUMPER
TRANSFORMER
C
G
Y
W
R
L
S1
S2
O/B
W2
Y2
RC
WIRING – TWO TRANSFORMERS (REMOVE
JUMPER WIRE) FOR HEAT/COOL SYSTEM
1st HEATING
1st COOLING
FAN
2nd HEATING
2nd COOLING
OUTDOOR TEMP
SENSOR
NOT USED
NOT USED
HEATING
TRANSFORMER
COOLING
TRANSFORMER
C
G
Y
W
R
L
S1
S2
O/B
W2
Y2
RC