Product Overview
features
+ Removes moisture from outdoor air before it enters
the live space
+ Unit is designed, when properly installed, to achieve
ASHRAE Standard 62.2-2010
+ Control is integrated into the unit
+ High and Low Temperature Limit Lock-outs
+ Simple plug-in installation
+ Installation temperature range up to 140°
BeNefIts
+ Helps control RH in the home during periods when
the air conditioning system does not run long enough
to remove sufficient moisture. If air conditioner
can satisfy RH requirements, the Aprilaire unit’s
compressor shuts off
+ Optimize energy savings by locking out ventilation
during hottest/coldest times of the day
+ Improves indoor air quality
+ Installation labor reduced, requires only a power
outlet and 24 volt wiring to HVAC system
When properly installed and set, the Aprilaire
Model 8191 and Model 8192 ventilators with
dehumidification will meet the mechanical
ventilation requirements of:
+ Energy Star Certified Homes, Version 3
+ EPA Indoor airPLUS, Version 1
+ 2012 & 2015 International Residential Code (IRC)
+ 2012 & 2015 International Energy Conservation Code
(IECC) – 8191 Only
35.50
27.50 4.004.00
10.00
10.00
12.50
15.08
14.50
1.38 to 2.00
3/4” PIPE, INSIDE
SpecificationS and Sizing Summary
model 8191 8192
Nominal Ventilation Airflow
(CFM)
100 CFM 200 CFM
Capacity
(1)
pints/day 70 ppd 95 ppd
Energy Factor
(1)
1.91 L/kW-h 2.2 L/kW-h
Energy Star Qualified Yes No
Air flow @ various external static pressure - dry coil
0.0 in WC 160 CFM 265 CFM
0.2 in WC 120 CFM 230 CFM
0.4 in WC 70 CFM 200 CFM
Voltage, Phase, Frequency 120VAC, 1, 60 Hz
Current Draw
(1)
6.3 amps 8.0 amps
Sound Level
47 dBA ducted
54 dBA ducted
51 dBA unducted
Dimensions - cabinet only
Width 12.5" 12.5"
Height
(2)
14.5" 14.5"
Length 25" 27.5"
Weight 70 lbs 75 lbs
Operating Condition
Inlet Air Operating Conditions 50°F - 104°F, 40°F dew point min.
Ambient/Ventilation 40°F - 140°F, 0% - 99% RH
(1)
Rated capacity and Energy Factor test done and current draw measure in accordance with AHAM DH-1 2008
at 80°F/60%RH inlet air at 0.0 ESP.
(2)
Height does not include adjustable feet or casters. The width excludes the filter doors, and length excludes
the duct collars.
SpecificationS
Control Built-in digital control with display
Control Mounting Option Field interchangeable from top to front
Cabinet Insulation 1/2" EPS
Air Discharge Orientation Top or end air discharge
Inlet/Outlet Duct Collars 10" round
Back Damper at Outlet Included
Air Filter Washable MERV 8
Refrigeration R-410A
Coil Corrosion Resistance E-coated coil
8’ Power Cord Type Plug type
Drain Connection 3/4" PVC adapters
(1)
Warranty 5 years
(1) Thread adapter and barbed fitting for clear drain tubing included.
8191/819 2
VENTILATOR WITH DEHUMIDIFICATION