Install Instructions
CONTROL
PANEL COVER
CONTROL
CONTROL
CONTROL
PANEL COVER
FILTER ACCESS DOOR
SET UP VENTILATOR FOR INSTALLATION (CONTINUED)
CONTROL LOCATION
The on-board control can be located on the top of
the ventilator or can be relocated to the front of the
ventilator.
To move the control:
1. Remove the front control panel cover.
2. Remove the filter access door and filter.
3. Detach the on-board control by removing the four
(4) screws around the control. NOTE: Use one
hand to support the bottom of the on-board control
when removing.
4. Keep the control in the unit and relocate to the
front access hole.
5. Secure the control with the same four screws
used to attach the control to the top of the unit.
6. Secure the control panel cover to the top of the
unit.
FIGURE 3 – Control Location
90-1884
LOCATION CONSIDERATIONS
TOP VIEW
FILTER
MINIMUM
CLEARANCE FOR FILTER
(EITHER SIDE)
13"
6" MINIMUM CLEARANCE
FOR PROPER AIR FLOW
ELECTRICAL SERVICE
ACCESS THIS SIDE
6 FT. POWER CORD
FIGURE 4 – Filter Access Clearance
90-1840
• Allow sufficient clearance for filter removal and to
prevent airflow obstruction
• Electrical service access will require the removal
of the side panel shown. Allow sufficient space for
service on this side of the unit.
• For attic installations, it is recommended that the
ventilator be suspended.
• Always install the ventilator in a condensate pan
when locating in or over a finished space.
5