Install Instructions

CLIP OFF
PLASTIC STRAP
REMOVE SHIPPING BRACKET
FIGURE 1 – Remove Shipping Bracket
90-1908
IMPORTANT: Cut the strap securing the compressor
shipping support bracket and remove the strap and shipping bracket.
See Figure 1.
SET UP VENTILATOR FOR INSTALLATION
STANDARD BASEMENT AND ATTIC INSTALLATIONS
(FULLY DUCTED)
Use the screws in the parts bag to attach the duct collars to the
inlet and outlet of the ventilator. The outlet collar has a backflow
damper.
The outlet duct collar may be attached to the top or end of the
unit. Move the outlet cover to the location not being used. See
Figure 2.
Make sure there are no bends in the ductwork coming off the
outlet for a minimum of 4”. This will ensure that the ductwork will
not interfere with the backflow damper function.
OUTLET COVER
OUTLET DUCT
COLLAR W/BACK
DRAFT DAMPER
MOVE OUTLET
COVER AND
INSTALL OUTLET
DUCT COLLAR TO
TOP DISCHARGE
LOCATION
INLET
DUCT
COLLAR
INLET
DUCT
COLLAR
END DISCHARGE
TOP DISCHARGE
FIGURE 2 – Duct Collar Locations
90-1909
DUCT COLLARS
4