INSTALLER CHECKOUT
The Installer checkout is entered
by holding the and buttons
for 7 seconds continuously. Upon
entering the Installer checkout all
outputs will turn off and thermostat
inputs will be ignored. The SYSTEM
CHECKOUT message will be
displayed for 2 seconds and then
transition to the first step of the
installer checkout as shown in the
diagram on this page.
Once in the installer checkout, the
and buttons will be used to
change selections.
In installer checkout, the zone panel
can only step forward through the
test steps so the Back button will
have effect.
The Next button will accept the
current setting and navigate to the
next step.
Minimum on time: The minimum
on and off times for heating and
cooling apply to the installer test.
The Time Delay Override button can
be used to speed up the minimum
on and off timers.
Timeout: Installer Checkout exits if
no button presses are detected for
10 minutes.
System Checkout
ZONES FOR TEST
ALL 1 2 3 4
TURN ON STAGE1 HEAT
YES NO
STAGE1 HEAT ON
DAT ##F
STAGE1 COOL ON
DAT ##F
STAGE2 HEAT ON
DAT ##F
STAGE2 COOL ON
DAT ##F
FAN ON
DAMPER ON
TURN ON FAN
YES NO
TURN ON DAMPER
YES NO
AUX1 HEAT ON
DAT ##F
AUX2 HEAT ON
DAT ##F
TURN ON STAGE1 COOL
YES NO
TURN ON STAGE 2 HEAT
YES NO
TURN ON STAGE 2 COOL
YES NO
OUTDOOR SENSOR
READS ##F
INSTALLER TEST COMPLETE
TURN ON AUX1
YES NO
TURN ON AUX2
YES NO
and Held
for 7 Seconds
Transition to
Home Screen
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Second Stage
Installed
Second Stage
Installed
All Dampers
Tested
Aux1 Installed
Aux2 Installed
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No
Note: A minimum off
time may be enforced
and an EQUIPMENT WAIT
message displayed.
English 17
61001165A 6403-6404 Zoned Comfort Control Install.indd 17 11/3/15 2:55 PM