Installation Manual

ZONE PANEL LAYOUT
TERMINALS
1. HVAC – HVAC connection
2. ZONE 1 THERMOSTAT – Thermostat connection
3. ZONE 2 THERMOSTAT – Thermostat connection
4. ZONE 3 THERMOSTAT – Thermostat connection
5. ZONE 4 THERMOSTAT (6404 only) – Thermostat connection
6. DAMPER 1 – Zone 1 damper connection
7. DAMPER 2 – Zone 2 damper connection
8. DAMPER 3 – Zone 3 damper connection
9. DAMPER 4 (6404 only) – Zone 4 damper connection
10. REMOTE SENSORS DAT (Discharge Air Temperature)
11. REMOTE SENSORS ODT (Outdoor Air Temperature)
12. EXPANSION (6404 only) – Expansion port (Model 6401)
13. DAMPER POWER – Damper power (dedicated 24VAC)
14. POWER – Zone panel and thermostat power (dedicated 24VAC)
LEDs
15. POWER – Green: 24VAC is present. Flashing: TDO button is pressed.
16. HEATING – Green: Heating is active. Flashing: DAT high temperature
limit reached.
17. COOLING – Green: Cooling is active. Flashing: DAT low temperature
limit reached.
18. FAN – Green: Fan output is active.
19. ZONE 1 – Green: Damper is open. Red: Damper is closed.
20. ZONE 2 – Green: Damper is open. Red: Damper is closed.
21. ZONE 3 – Green: Damper is open. Red: Damper is closed.
22. ZONE 4 – Green: Damper is open. Red: Damper is closed.
23. EM HEAT – Amber: Emergency Heat mode is enabled using the
EM Heat button or an Emergency Heat call is active based on a
thermostat Emergency Heat call.
24. VACATION – Green: Vacation mode is enabled.
BUTTONS
25. EM HEAT – Used to enable/disable Emergency Heat mode. In
Emergency Heat mode the compressor will be locked out and only
auxiliary heat will be used to satisfy heating calls. NOTE: The EM
Heat button does not function when the zone panel is configured to
control conventional equipment.
26. VACATION – Used to enable/disable Vacation mode. In Vacation
mode all zones will be controlled by the thermostat in Zone 1.
27. Navigation buttons – Used for installer setup and checkout.
28. TDO (Time Delay Override) – Accelerates timing (6 seconds = 1
minute). Used to speed up equipment protection minimum on and
off timers.
29. Wireless Outdoor Sensor Connect – Used to link an optional
outdoor temperature sensor to the zone panel.
LCD
30. In normal operation, displays zone panel status. In installer setup,
used to configure the zone panel. In installer checkout, used to step
through the installer test.
WIRELESS OUTDOOR SENSOR
31. Placement of optional Model 8056 wireless outdoor radio module.
15
26
25
8
7
6
9
27
28
11
10
5
29
1
12
13
14
31
2
16
17
18
19
20
21
22
24
3
4
23
30
90-2084
FIGURE 2 – ZONE PANEL LAYOUT
4 English