User Guide

SPECIFICATIONS
INPUT RATINGS
Voltage: 18-30VAC 50/60 Hz
MAXIMUM CURRENT
Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F
Zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F
Zone panel consumption: 4VA max
Note: Use 18 or 20 AWG solid (non-stranded) wire
ENVIRONMENT
Temperature (operating): 32°F – 158°F
Temperature (shipping): -40°F – 180°F
Humidity: 5% – 90%, non-condensing
DIMENSIONS
See FIGURE 1.
8.63 (219)
9.66 (245)
1.86 (47)
90-2468
FIGURE 1 – ZONE PANEL DIMENSIONS IN INCHES (mm)
APPLICATION & ACCESSORIES
APPLICATION
The Model 6303 and 6302 Zone Panels are for heat pump applications. The
Model 6303 is for 3-zone installations and the 6302 is for 2-zone installations.
The features include:
2 heating and 1 cooling stage
Equipment protection
Vacation mode – Zone 1 thermostat controls all zones
Emergency Heat mode – Locks out the heat pump for heating
ACCESSORIES
Discharge Air Temperature Sensor (DAT):
Model 8052 (included)
English 3