Install Instructions

TABLE 9: HEAT COOL INSTALLER SETTING
HVAC Equipment Outputs
Test Step Test Description Y Y2 W W2 O B G
1 Stage 1 Heat, Heat Cool OFF OFF ON OFF OFF ON ON
2 Stage 2 Heat, Heat Cool OFF OFF ON ON OFF ON ON
3 Stage 1 Cool ON OFF OFF OFF ON OFF ON
4 Stage 2 Cool ON ON OFF OFF ON OFF ON
5 Fan OFF OFF OFF OFF ON OFF ON
IAQ Equipment Outputs
Test Step Test Description HUM/AUX DEH VENT G
6 Humidifier ON OFF OFF ON
7 Dehumidifier OFF ON OFF ON
8 Ventilation OFF OFF ON ON
Damper Equipment Outputs
Test Step Test Description Damper 1 Damper 2 Damper 3 G
9 Damper 1 OPEN CLOSED CLOSED OFF
10 Damper 2 CLOSED OPEN CLOSED OFF
11 Damper 3 (3 zone systems only) CLOSED CLOSED OPEN OFF
TABLE 10: HEAT PUMP INSTALLER SETTING
HVAC Equipment Outputs
Test Step Test Description Y Y2 W W2 O B G
1 Stage 1 Heat, Heat Pump ON OFF OFF OFF OFF ON ON
2 Stage 2 Heat, Heat Pump ON ON OFF OFF OFF ON ON
3 Aux 1 Heat, Heat pump OFF OFF ON OFF OFF ON ON
4 Aux 2 Heat, Heat pump OFF OFF ON ON OFF ON ON
5 Stage 1 Cool ON OFF OFF OFF ON OFF ON
6 Stage 2 Cool ON ON OFF OFF ON OFF ON
7 Fan OFF OFF OFF OFF ON OFF ON
IAQ Equipment Outputs
Test Step Test Description HUM/AUX DEH VENT G
8 Humidifier ON OFF OFF ON
9 Dehumidifier OFF ON OFF ON
10 Ventilation OFF OFF ON ON
Damper Equipment Outputs
Test Step Test Description Damper 1 Damper 2 Damper 3 G
11 Damper 1 OPEN CLOSED CLOSED OFF
12 Damper 2 CLOSED OPEN CLOSED OFF
13 Damper 3 (3 zone systems only) CLOSED CLOSED OPEN OFF
24