Install Instructions

WIRING
WIRE SPECIFICATIONS:
18-24 gauge thermostat wire
INSTALLATION NOTES:
Control to Hub
Ensure power at the 6000 Series Hub is off.
Insert stripped wire (Hub).
Loosen screw terminals (Control), insert stripped wire and re-tighten.
Push the excess wire at Control, back into the opening and plug the
wall opening to prevent drafts.
1 – Connect Control terminal 1 to Hub terminal 1
2 – Connect Control terminal 2 to Hub terminal 2
3 – Connect Control terminal 3 to Hub terminal 3
4 – Connect Control terminal 4 to Hub terminal 4
Sensor to Hub
Ensure power at the 6000 Series Hub is off.
Insert stripped wire (Sensor & Hub).
Push the excess wire at Sensor, back into the opening and plug the
wall opening to prevent drafts.
1 – Connect Sensor terminal 1 to Hub terminal 1
2 – Connect Sensor terminal 2 to Hub terminal 2
3 – Connect Sensor terminal 3 to Hub terminal 3
4 – Connect Sensor terminal 4 to Hub terminal 4
90-2423
90-2424
FIGURE 21 – 4-WIRE CONNECTION, 6000 SERIES CONTROL
FIGURE 22 – 4-WIRE CONNECTION, 6000 SERIES SENSOR
14