Specification

MODEL 65 SPECIFICATIONS
Electrical External
Input voltage and current
Voltage: 24VAC (supplied by
humidier control board)
Control External
Control range 10%-50% RH
Accuracy ±5%
Differential 3%
Operating ranges
40°F – 99°F
5% - 90% RH (non-condensing)
DISCHARGE
REGISTER
ROOM 1
OUTLET
DUAL OUTLET FOR MODEL 300
MODEL 300
HUMIDIFIER
.
.
INLET
REGISTER
INLET
DISCHARGE
REGISTER
ROOM 2
DUAL OUTLET FOR MODEL 300
DUCTED RETURN AND
DUCTED SUPPLY
DUCTLESS RETURN AND
DUCTED SUPPLY
Form No. 365 • 313219 • 10.22
© 2022 AprilAire | aprilairepartners.com | 800.334.6011
AprilAire reserves the right to change specications without notice.
DEDICATED MONITORING
INSTALLATION OPTIONS FOR THE MODEL 300
Model 65
Dedicated monitoring
and control of the
humidier from the
living space.
Disclaimer:
Using multiple discharge registers may lead to unequal humidity levels.
Air ow favors the path of least resistance, so shorter, straighter duct runs will receive more
humidied air than runs that are longer and have more bends or transitions. Over time,
humidity will equalize throughout the living space.
Discharge registers should be placed on an interior wall.
The unit can be mounted off the joists or in between joists which
are spaced at least 14.5” apart. Hard duct or ex duct can be used.
The sound of the unit decreases when using ex duct.