Install Instructions

LOCATION CONSIDERATIONS
TOP VIEW
FILTER
MINIMUM
CLEARANCE FOR FILTER
(EITHER SIDE)
20"
6" MINIMUM CLEARANCE
FOR PROPER AIR FLOW
ELECTRICAL SERVICE
ACCESS THIS SIDE
6 FT. POWER CORD
FIGURE 2 – Filter Access Clearance
90-2042
Allow sufficient clearance for filter removal and
to prevent airflow obstruction
Electrical service access will require the removal
of the side panel shown. Allow sufficient space
for service on this side of the unit.
If locating the unit in an attic or crawl space, a
Model 76 Control mounted in the living space
is recommended. Refer to Model 76 Installation
Instructions and Owner’s Manual.
Always install the dehumidifier in a condensate
pan when locating in or over a finished space.
CUT OFF
PLASTIC STRAP
REMOVE SHIPPING BRACKET
FIGURE 1 – Remove Shipping Bracket
90-2040
IMPORTANT: Cut the strap securing the compressor
shipping support bracket and remove the strap, shipping bracket
screws, and bracket. See Figure 1.
SET UP DEHUMIDIFIER FOR INSTALLATION
3