Submittal Sheet

33.00
25.00 4.004.00
10.00
10.00
12.50
15.08
14.50
1.38 to 2.00
3/4” PIPE, INSIDE
33.00
25.00 4.004.00
10.00
10.00
12.50
15.08
14.50
1.38 to 2.00
3/4” PIPE, INSIDE
33.00
25.00 4.004.00
10.00
10.00
12.50
15.08
14.50
1.38 to 2.00
3/4” PIPE, INSIDE
HARDWIRE OPTION: Field configurable
SPECIFICATIONS
Capacity
(1)
(water removal)
70 ppd
Energy factor
(1)
(eciency)
1.9 L/kWh (3.85 pints/kWh)
Voltage, Phase, Frequency 120 VAC, 1 Phase, 60Hz
Current draw
(1)
6.3 Amps
Airow 160 CFM @ 0.0"w.c., 70 CFM @ 0.4"w.c.
Sound level 47 dBA ducted; 51 dbA not ducted
Dimension
(cabinet only)
(2)
Width: 12½"
Height: 14½"
Length: 25" without collar; 33" with collar
Weight 67 lbs.
Control Built in digital control with display
Filter Washable MERV 8
Refrigerant R410A
Coil type Corrosion resistant aluminum coil
Power cord 8' power cord with plug
Duct connection 10" round
Drain connection
(3)
3/4” nominal drain tubing; Supplemental
barb fitting for 1/2" clear drain tubing
Control mounting Field interchangeable from top to front
Cabinet insulation 1/2" EPS
Air discharge Interchangeable from end to top
Duct collars 10" round at inlet and outlet
Backdraft damper Included in outlet duct collar
Warranty 5 Years on all parts
(1)
Rated capacity and energy factor test done and current draw measured
in accordance with AHAM DH-1 2008 at 80°F/60% RH inlet air at 0.0 ESP.
(2)
Filter rack adds 3⅜”.
(3)
Requires drain trap.
The submittal is intended to show general, overall product dimensions and provide guidance for installation clearance. Drawings are not to scale.
Ensure submittals are current. Research Products reserves the rights to make product change without notifications or obligations.
P.O. Box 1467
Madison, WI 53701-1467
800.334.6011 F: 608.257.4357
AprilairePartners.com
Form No. Sub-1830 • 281871 07.18
©2018 Aprilaire Division of Research Products Corporation
Dehumidifier
MODEL 1830 | SUBMITTAL SHEET
Project: _____________________________________
Architect: ___________________________________
Contractor: __________________________________
Suppliers: ___________________________________
Dealer: _______________________________________________
Engineer: ______________________________________________
Location: ______________________________________________
Date: _________________________________________________
OPERATION
The Aprilaire 1800 Series dehumidifiers are designed to dehumidify the air coming into the unit
by passing the incoming air over an evaporator coil, dropping the air temperature below the dew
point. The moisture is removed from the air and drains out of the dehumidifier to a common floor
or waste drain. The air is then reheated in the condenser coil and exits the unit.
Dehumidification occurs until the relative humidity (%RH) setting is reached. The unit then shuts o
until periodic sampling determines the need for dehumidification. The integrated digital display
and control monitors the %RH during sampling of the incoming room or HVAC return air.
APPLICATION
All the Aprilaire 1800 Series dehumidifiers are the perfect product for whole-home
dehumidification, basements, crawl spaces and sealed attics.
VENTILATION
All 1800 Series models have the ability to bring in fresh, outdoor air into the living space. Fresh air
will dilute stale air and pollutants and will reduce humidity in the winter months. If the humidity
level of the outdoor air higher than the %RH setting, the dehumidifier will begin dehumidification to
reduce the humidity in the home to set humidity level. The outdoor fresh air is brought in through 6"
round duct with a 6" round, normally closed damper. This complies with ASHRAE 62.2-2010, Energy
Star, and 2012 International Residential Code (IRC).
The dehumidifier has built in controls to adjust the amount of fresh air that is brought in to the
home. If wired to the HVAC system, the dehumidifier will bring in the outdoor air when the HVAC
system calls for heating, cooling, or is running continuous fan. If the amount of set ventilation
time has not been met during the HVAC calls, the dehumidifier will open the ventilation damper
and turn on the HVAC fan and bring in fresh air until the ventilation time has been met.
High and low temperature limits are available in 3 dierent modes, preventing outdoor air that is
too hot or too cold from being delivered to the home. If the outdoor temperature rises above the
high limit or drops below the low limit, ventilation will not occur. If the outdoor temperature drops
below the heat only limit, ventilation will be allowed only when the HVAC system is calling for
heat. A high indoor %RH limit is also available in all three ventilation modes.
ZONED DEHUMIDIFICATION
The 1800 Series dehumidifiers are capable of zoned dehumidification. In this application,
the dehumidifier can control the humidity in two separate zones in the home, a Primary and
Secondary Zone.
90-1921