Specifications

2
FIGURE 1 – Dimensions of the Model 5000 Electronic Air Cleaner
© Research Products Corporation 2008
31" with Door
28-1/8" without Door
12"
24-5/8"23-7/8"
15-1/2"
17-3/4"
21"
19-5/8"
90-1346
SPECIFICATIONS
TABLE 1 – Initial Airflow Resistance (inches w.c.)
Model
Airflow (CFM)
1000 1200 1400 1600 1800 2000
5000
.10 .14 .17 .21 .25 .29
Electrical – Voltage:
Door: 120 VAC ± 15% @ 50/60 Hz
Control: 18-30 VAC
Electrical – Current/Power:
Door: Consumes less than 50 watts with high voltage active.
Control: 2A maximum low-voltage current for fan control
0.3-0.4 µm Particle Filtration Efficiency @ 347 fpm: 94%
Replacement Media: Model 501
Airflow Capacity: up to 2000 CFM maximum
Max. Equipment Weight:
Cabinet will support 400 lb. static load
Air Cleaner and LED Base Operating Environment:
Temperature: 32°F – 140°F
Humidity: 0-90% non-condensing
Air Cleaner Control Operating Environment:
Temperature: 20°F – 120°F
Humidity: 0-90% non-condensing
Do not wire the Control to EAC terminals of HVAC system.
These terminals are 120 Volts and will damage the Air
Cleaner Control.
CAUTION
DIMENSIONS
These instructions are for Model 5000's manufactured May 2008 and Later.