Installation Instructions

5
12. Confirm that no wires contact the printed circuit board or associated
components inside the Ara, especially the bare portion of the ground wire.
Attach the cover to the Controller using the four screws removed earlier.
13. Turn the electricity on at the circuit breaker. The Green LED will illuminate on
the controller indicating that the relay is closed and power is connected to the