8. TROUBLESHOOTING
8.1. MODULE NOT APPEARING IN VISTALINK
®
Ensure that the module is in the right hand slot (if places in the left hand slot it will power up, but
not communicate over Ethernet).
Ensure that the Ethernet port has activity (LED’s on the port should light). If there is no activity,
check the Ethernet connection.
Ensure that a valid IP address has been entered in the module through the serial port.
Attempt a ping to the unit from the VLPro computer. If a ping is unsuccessful, reconfirm that the IP
address of the module is entered in correct, and is on the same subnet logically and physically that
the VLPro computer is on.
Ensure that the correct JAR file has been added to VLPro (goto the VLPro help menu, select
Version Information, and scroll through the list to find the 7700ACO2-HD). If it does not appear,
contact Evertz Service for the latest file.
Attempt to add the module manually to the VLPro hardware tree. If the module comes up, but is
displayed as a question mark, shutdown VLPro and deleted the following file vistalink install
path”/config/VistalinkAgentStandaloneInfo.xml, and restart VLPro.
8.2. INTELLITRAK/INTELLIGAIN OPTIONS ARE NOT AVAILABLE IN VLPRO
Ensure that the module was ordered with the correct options. To check the options installed, see
Section 6.3.1.
Ensure that the correct JAR file has been added to VLPro (go to the VLPro help menu, select
Version Information, and scroll through the list to find the 7700ACO2-HD). If the version is older
than the one specified in this manual, contact Evertz Service for the latest file.
8.3. VIDEO SOURCES ARE NOT BEING DETECTED
Ensure that the loop through outputs of the video inputs are terminated to 75Ω. If left open or
floating, the module will not be able to lock to the signal.
Ensure that the module output has been set to the correct video standard.