Specifications

7700/7800 MultiFrame Manual
7700ACO2-HD Dual HD/SD-SDI Smart Automatic Changeover
Revision 1.0 Page - 33
5.9.1. Fault Duration
FD11/FD12
This parameter sets the number of frames that the error condition is held
once a fault is generated.
1 to 254 (30)
5.9.2. Fault Logic
FL11/FL12
This parameter sets the logic condition for fault collection.
OR Any one of the monitored fa
ults occurring will cause the fault
condition to become active.
AND Only when all the monitored faults occur will the fault condition
become active.
OR
AND
5.9.3. Video Loss Select
VL11/VL12
This parameter sets whether video loss is used to determine a fault
condition.
ONThe parameter is used in determining a fault condition.
OFFThe parameter is not used in determining a fault condition.
ON
OFF
5.9.4. Video Freeze Select
VF11/VF12
This parameter sets whether video freeze is used to determine a fault
condition.
ONThe parameter is used in determining a fault condition.
OFFThe parameter is not used in determining a fault condition.
ON
OFF
5.9.5. Video Black Select
VB11/VB12
This parameter sets whether video black is used to determine a fault
condition.
ONThe parameter is used in determining a fault condition.
OFFThe parameter is not used in determining a fault condition.
ON
OFF