5.9.1. Fault Duration
FD11/FD12
This parameter sets the number of frames that the error condition is held
once a fault is generated.
1 to 254 (30)
5.9.2. Fault Logic
FL11/FL12
This parameter sets the logic condition for fault collection.
OR – Any one of the monitored fa
ults occurring will cause the fault
condition to become active.
AND – Only when all the monitored faults occur will the fault condition
become active.
OR
AND
5.9.3. Video Loss Select
VL11/VL12
This parameter sets whether video loss is used to determine a fault
condition.
ON – The parameter is used in determining a fault condition.
OFF – The parameter is not used in determining a fault condition.
ON
OFF
5.9.4. Video Freeze Select
VF11/VF12
This parameter sets whether video freeze is used to determine a fault
condition.
ON – The parameter is used in determining a fault condition.
OFF – The parameter is not used in determining a fault condition.
ON
OFF
5.9.5. Video Black Select
VB11/VB12
This parameter sets whether video black is used to determine a fault
condition.
ON – The parameter is used in determining a fault condition.
OFF – The parameter is not used in determining a fault condition.
ON
OFF