Specifications
7700/7800 MultiFrame Manual
7700ACO2-HD Dual HD/SD-SDI Smart Automatic Changeover
Page - 10 Revision 1.0
10. Once all the settings for the Network Setup have been configured, the user can type x to exit the
Network Setup configuration.
11. Skip to step 18 if you are not using SNMP Trap Monitoring.
12. Next the user will need to configure the SNMP Setup. To do so, return to the main menu screen,
as shown in Figure 2-5, and select option <2> SNMP Setup.
13. A Trap Setup Menu will appear as shown in Figure 2-7. To create a trap destination, select option
<1> Add Trap Destination.
14. The user will be prompted to enter a destination IP address into the “Enter IP of New Destination”
field.
15. The user can enter multiple trap destinations as outlined in steps 11 and 12. To remove a trap
destination, select option <2> Remove Trap Destination from the menu.
Figure 2-7: Trap Setup Menu
16. The user will be prompted to enter the destination IP address of the trap destination which they
wish to remove.
17. The user can view the trap destinations assigned to the card by selecting option <3> Show All
Trap Destinations. A list of trap destinations will be displayed as shown in Figure 2-8. To exit the
Trap Setup Menu, select the <x> Exit and you will return to the Main Menu.