2.4. CONFIGURING THE NETWORK SETTINGS
In order to configure the module through SNMP, a network connection must be established. Network
settings are configured through a serial connection (using a terminal program such as HyperTerminal),
using the instructions below:
1. Attach a serial ribbon cable (Evertz Part Number: WA-S67, see “Upgrading Firmware” manual) to
the J3 jumper on the top of the card, and plug the other end of the serial cable into the COM port
on your computer.
2. Insert the card into the frame and power up the unit.
3. Open a serial terminal session and enter the following port settings into the properties window:
Baud
115200
Parity
None
Data Bits
8
Flow Control
None
Stop Bits
1
Once the settings have been entered select the “OK” button.
4. Once the module is fully booted, there will be a prompt to enter a username and password. Use
the following username and password to login:
Login: config
Password: config
5. Once logged in, the user will be presented with a Main Menu setup screen as shown in Figure 2-5.