Installation guide
  7800 Series Keypad Installation Guide  11
  Site Code Position
Enter the site code start position in the data string. Press 
any select area to enter a number between 0-255. Press 
COMMAND to save the entry. Default is 1.
  Site Code Length
Enter the number of characters the site code contains. 
Press any select area to enter a number between 1-16. 
Press COMMAND to save the entry. Default is 8.
  User Code Position
Dene the User Code start bit position. Press any select 
area to enter a number between 0-255. Press COMMAND 
to save the entry. Default is 9.
  User Code Length
Dene the number of User Code bits. Press any select 
area to enter a custom number. Custom numbers can only 
be a number between 16-32. Press COMMAND to save the 
entry. The default is the DMP value of 16.
REQUIRE SITE 
CODE:    NO  YES
  Require Site Code
Press YES to use a site code, for non-DMP cards, and press 
CMD to view the site code entry display. Default is NO.
In addition to User Code verication, door access is only 
granted when any one site code programmed at the SITE 
CODES entry option matches the site code received in the 
Wiegand string. You can program up to eight three-digit 
site codes.
Note: A card with a site code greater than three digits 
cannot be used. Use only cards with three-digit 
site codes.
SITE CODES 1-4
> > > >
  Site Codes 1-4
Enter site codes 1-4 (left to right separated by > sign). 
Press the > sign to add, delete, or change the site code. 
Press COMMAND to save the entry. 
Site code range is 0-999.
SITE CODES 5-8
> > > >
  Site Codes 5-8
Enter site codes 5-8 (left to right separated by > sign). 
Press the > sign to add, delete, or change the site code. 
Press COMMAND to save the entry. 
Site code range is 0-999.
  No Communication With Panel
This option denes the relay action when communication 
with the panel has not occurred for ve seconds. Press 
any select area to display CHOOSE ACTION.
The default is Relay Always Off.
Choose the No Communication with Panel action that 
is required.
 Press OFF to choose [Default] (Relay Always Off)  — 
The relay does not turn on when any Wiegand string is 
received. Off does not affect any REX operation.
SITE CODE:   
POSITION  1
SITE CODE:   
LENGTH  8
USER CODE:   
POSITION  9
USER CODE:   
LENGTH  16
NO COMM WITH PNL
 OFF
CHOOSE ACTION
OFF SITE ANY ON