User's Manual
Table Of Contents
- UA-612 Installation Sheet V1.2
- Reader Description
- Parts List
- Installation Procedure
- Product Specifications
- Cable to Controller and Power Supply
- Reading Distance
- Notes
- 1. Connect the black wire (negative) first, and the red wire (positive) last. Disconnect power before any wiring changes.
- 2. The LED and Beeper lines are logic levels. Never apply power to them. They may be pulled to a low level (0 to 1.2 VDC) to enable their functions, and left floating or pulled to a high level (3.6 to 5.0 VDC) when not used.
- 3. UA-612 readers have both Wiegand-protocol and RS-232 serial interfaces. For information on RS-232, contact AWID’s technical support.
- 4. For additional information, please visit AWID’s Web site www.awid.com. For technical support questions visit www.awid.com/support or call 1-800-369-5533 (in the U.S.) or 1-408-825-1100 from 8:00 a.m. to 5:00 p.m. Pacific Time.
- 5. FCC Compliance: This equipment has been tested and found to be in compliance with the limits for FCC part 15, Class A digital device. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
- The users are prohibited from making any change or modification to this product. Any modification to this product shall void the user’s authority to operate under FCC Part 15 Subpart A Section 15.21 regulations.
- This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
- UserManual
MPR-2010-2.7E4-CN Page 11 7/22/2008
0.15
0
0.25 0.5
0.75
R
0
Distance
(R)
W
i
d
t
h
(
W
)
W (0.72R)
Figure 1 MPR 2010-2.7E4-CN Antenna Pattern
• Antenna pattern measurements represent both horizontal and vertical polarized
planes of the read area transmitted by the reader.
• In the drawing above, R = approximately 12 feet to 15 feet for MPR-2010 with
Alien free space tags.
• Antenna pattern can be affected by RFI and other environmental conditions.
4.2.3 Mounting Considerations
Antenna Mounting Bracket
Available from AWID is an optional
antenna-mounting bracket that provides
antenna tilt adjustment and pan
adjustment.
4.3 INSTALLATION STEPS
1) Check to ensure that all connections are secure. Make sure all wires through the
cable clamps are anchored properly. Avoid dangling wires that may become a
safety hazard.