- 1. Connect the black wire (negative) first, and the red wire (positive) last. Disconnect power before any wiring changes.
- 2. The LED and Beeper lines are logic levels. Never apply power to them. They may be pulled to a low level (0 to 1.2 VDC) to enable their functions, and left floating or pulled to a high level (3.6 to 5.0 VDC) when not used.
- 3. UA-612 readers have both Wiegand-protocol and RS-232 serial interfaces. For information on RS-232, contact AWID’s technical support.
- 4. For additional information, please visit AWID’s Web site www.awid.com. For technical support questions visit www.awid.com/support or call 1-800-369-5533 (in the U.S.) or 1-408-825-1100 from 8:00 a.m. to 5:00 p.m. Pacific Time.
- 5. FCC Compliance: This equipment has been tested and found to be in compliance with the limits for FCC part 15, Class A digital device. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
- The users are prohibited from making any change or modification to this product. Any modification to this product shall void the user’s authority to operate under FCC Part 15 Subpart A Section 15.21 regulations.
- This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
- UserManual
MPR-2010-2.7E4-CN Page 8 7/22/2008
TABLE 3.4-1: Data Line’s Wiring Requirement
WIRE SIZE #22 AWG (0.6 mm Dia.) #24 AWG (0.5 mm Dia.)
WIEGAND (*) 500 ft (152 meters) 980 ft (300 meters)
RS-232 50 ft (15 meters) 50 ft (15 meters)
(*) LR-911 only
3.5 GROUNDING
Grounding is critical for proper operation of MPR-2010-2.7E45V-CN readers. When
installing the reader, it is crucial to assure that the earth ground is the best ground
available. If you elect to use the 120 VAC power ground, conduct a test by measuring
its resistance relative to a known good ground, such as a cold water pipe or structural
steel that is in direct contact with the ground. The resistance should be less than 50
ohms.
When using the GP I/O for sensing or display functions with a BN unit, make sure there
is no ground loop between the different sensors or displays.
For multiple LR-911 installations, it is critical that all units are connected to the same
grounding system. Using different grounding systems will create secondary current
paths or ground loops that can affect the performance and cause damage to LR-911.