User's Manual

SC-2300 - 11 - 2/5/2007
Your best option for Proximity Access Control
Panel sends an acknowledgement or until the card is removed from the
reader. You can repeat this action by placing the card in front of the reader
after the LED turned RED. If the Panel did not send a logic “HIGH” LED
(brown) command to the reader, the reader will “latched” and must be
powered off to re initialize.
4.4 MOUNTING
1. Connect the remaining wires to the Panel.
2. Mount the Reader securely to the electrical junction box with #6-32x1
machine screw, (Item c on Parts List.)
3. Install the Snap-On cover.
5 Warranty
AWID’s products are warranted to the original purchaser to be free of defects in material
and workmanship for the life of the product. Any tampering or modification to the
product will void this product warranty. AWID does not warrant any product as to its
merchantability or suitability of use. AWID's sole and complete responsibility under this
warranty is expressly limited to repair or replacement of the warranted product.
6 Return Material Authorization (RMA)
AWID monitors and tracks the life cycle performance of our product through our RMA
system. All customers must obtain a RMA number from AWID Customer Service
Department prior to returning the merchandise. After the customer provides AWID
Customer Service Department with the serial number and a description of the returning
item, a RMA number will be issued. This RMA number must be clearly marked on
the outside of the returned package and noted on the paperwork attached to the
returned merchandise.
When obtaining a RMA number for RFID tags, please provide AWID Customer Service
Department with the serial numbers, card identification numbers, facility codes and etc.
If exact duplicates of returned cards or tags are requested, the customer must provide
AWID with the numbers needed. AWID reserves the option to replace or repair returned
merchandise.
Items returned to AWID without the proper authorization will be returned to the
originators at their own expense.
7 Troubleshooting
This unit, if not installed in strict compliance with AWID’s installation instructions, may
not function to specifications. Use the checklist below to identify the problem:
Is the card valid and working? - Try some different cards!
Is the reader wired correctly? - RED-BLK :7-12V, reader should work
Is the unit grounded properly? - DRAIN-EARTH: less than 50 Ohms