Installation Instructions

Instructions LR-911, Part 2 14 September 2005 Page 7 of 8
NOTES for Figure 1
1. Separate the unused wires. Keep the unused wires isolated.
2. On some earlier LR-911 readers, the spring clip on the orange wire of the test unit must connect
to the reader’s violet wire. If the orange-to-orange connection does not work, use an
orange-to-violet connection.
NOTES for Figure 3
1. When running Microsoft HyperTerminal, tie the reader’s yellow wire to the black wire.
When running AWID’s LR-911 programs, leave the yellow wire unconnected.
2. On some earlier LR-911 readers, the orange and violet spring clips of the adapter cable must be
reversed – orange-to orange and violet-to-violet instead of the connections shown in Figure 3.