5.2 Installation Steps
a. Position the Reader at the appropriate mounting position.
b. Drill four 7/64 (0.109)-inch holes as shown on the installation instruction.
c. For mounding surface smaller than 8X8 inches: remove the top cover and drill
appropriate mounting holes on the base plate of MR-1824.
d. Drill one clearance hole for the cable and wiring lug.
e. Guide the open end of the Panel’s control cable through the clearance hole.
f. Connect the Reader and the Panel together according to Figure 5.2-1 for Wiegand format
and Figure 5.2-2 for RS-232 and Figure 5.2-3 for Wiegand/RS-232 format.
5.3 Verification
a. Power up the PANEL, the LED on the Reader should show RED.
b. Place a “good” card in front of the Reader and keep it in that position. The reader will
give out “ONE” audible BEEP and the LED will change from RED to AMBER momentarily
and than flashing between RED & GREEN. The reader will stay flashing until the panel
sends an acknowledgement or until the card is removed from the reader. You can repeat
this action by placing the card in front of the reader after the LED turned RED.
c. The reader uses an internal micro-controller to manage its many functions, and the
micro-controller must be initialized properly. When the reader show evidence of mail
functioning, turn off the reader and wait for five seconds before energize the reader
again.
Fig. 5.2-1 Wring Diagram for Wiegand Output Format
Fig. 5.2-2 Wiring Diagram For RS-232 Output Format
AWID PROPRIETARY