Installation Procedure
1.) Position the Reader (Item b on Parts List) at the desired mounting position on a
mounting post or a mounting surface. Use Figure. 1 as guide. For straight mounting,
drill four small holes for mounting screws, and one clearance hole for reader cable.
The installer determines the size of the mounting holes and the clearance hole.
2.) For straight mounting, insert both cable slot plugs (item g on Parts List) to bottom
cover.
3.) For side mounting, bend and press the cable into the curved channel and guide the
cable out on the desired side of the LR-911. Insert one cable slot plug to the other
side of the bottom cover with no cable coming out.
4.) For Wiegand output, connect the Reader and the Panel together according to Figure
2. Install reader onto the mounting surface with items c, d, and e on Parts List. (For
other data format, see Note 3.)
5.) Read Note 1 and below then insert item f. on Parts List into the four screw clearance
holes to conceal the screws.
5.3 Verification
a. Power up the PANEL, Connect a PC, which has the special test program installed, at the
RS-232 output port.
b. Place a “good” card in front of the Reader and keep it in that position. The reader
program will confirm that the data has been detected.
c. The reader uses an internal micro-controller to manage its many functions, and the
micro-controller must be initialized properly. When the reader show evidence of
malfunctioning, turn off the reader and wait for ten seconds before energize the reader
again.
AWID PROPRIETARY