User's Manual
6
TABLE 4.4-1: Data Line’s Wiring Requirement
WIRE SIZE #22 AWG (0.6mm Dia.) #18 AWG (1.2mm Dia.)
WIEGAND 500 ft (152 meters) 980 ft (300 meters)
RS-232 45 ft (15 meters) 45 ft (15 meters)
4.5 Power Supply
For consistent performance, choose a Low Noise/High Efficiency switching power supply
4.7 Grounding
Grounding is critical for proper operation of the Reader. When installing the Reader, it is crucial
to assure that the earth ground is the best ground available. If you elect to use the AC main
power ground, conduct a test by measuring its resistance relative to a known good ground, such
as a cold water pipe or a structural steel that is in direct contact with the ground. The resistance
should be less than 50 ohms. If you find that the AC main power does not provide adequate
earth ground, try using a solid connection to a cold water pipe.
Outer shield of cable should not be grounded.
For multiple Reader installations, it is critical that all Readers are connected to the same
grounding system. Using different grounding systems will create secondary current paths or
ground loops that can affect the performance and cause damage to the Reader.
4.8 Wiring Diagrams
See Fig’s 5.2-1,2,3
5.0 INSTALLATION PROCEDURE
Verify that all item listed in Section 5.1 of this manual are present before starting the installation.
5.1 Parts List
A. Installation sheet, P/N: 006-99-A QTY=1
B. Sentinel-Prox LR-911 Reader, P/N: 004-20-A QTY=1
C. #6-32 x 1” Machine screw, P/N: 0616MPP QTY=4
D. #6-32 Hex Machine Screw Nuts, P/N: 06NH QTY=5 (1 spare)
E. #6 External Tooth Lockwashers, P/N: 06WE QTY=5 (1 spare)
F. Screw hole plug, P/N: 004-27-A QTY=5 (1 spare)
AWID PROPRIETARY
5.2 Installation Steps