Technical data
QF150SU; edition 2014-10; page 6 of 19
If hoses were used in the suction line, make sure that they do not collapse due to the negative
pressure.
When installing the pump please consider that around the pump enough space is available for
operation and maintenance. Pay attention to the required space needed for assembly and
disassembly of the pump chamber (see 4.1.1.).
During start-up pay attention to the warning and safety instructions of the following chapter 3
of this manual.
2.4. Control panel
In the Quattroflow 150 SU pump is operated with a 50 W brushless Panasonic motor. You can modify
the speed of the motor by the control panel on the top of the pump.
Main switch. Push to start – the panel lights up
Push to speed up (arrow bottom-up) or to speed
down (arrow top down)
Push "Green button" RUN, to start the pump
“MOD button“ Switch between rpm, effiency %,
motor power V
Display show: "rpm, %, V"
(max. speed 3.000 rpm)
Push the "Red button" STOP to stop the pump
Attention: The optimal motor parameter are set by the factory.
Only authorized and qualified personnel should change the parameter of the control panel!
Attention!
You must study the operating instructions of the PANASONIC–Motor before
you make any changes of the parameter!
2.5. Cleaning (CIP)
The pump chamber has been designed for single use only. Cleaning is not necessary, as the pump
chamber is replaced after each use.