Technical data
QF150SU; edition 2014-10; page 18 of 19
7. Technical data of the QF 150 SU
Description
Unit
QF150 SU
Standard Motor
Flow rate max.:
Eccentric shaft 5°
l/h (gph)
180 (48)
Flow rate min.:
Eccentric shaft 5°
l/h (gph)
1
Pressure:
Temperature of fluid < 40°C
bar (psi)
4 (58)
Temperature of fluid > 40°C
bar (psi)
3 (43)
Temperature max.:
Fluid
°C (°F)
60 (140)
Autoclave
°C (°F)
130 (260)
Suction lift dry at:
3000 rpm
Eccentric shaft 5°
m (ft)
2-3 (6.6-9.8)
Volume specifications:
Approximated volume per revolution at free output
ml
1,2
Filling volume without connectors
ml
15
Residual volume (after idle with high-speed motor)
ml
1-3
Product wetted surface (approx.)
cm² (inch²)
112 (17)
Speed range pump
rpm
10-3000
Connection specification inlet (standard)
Connector
"
1/4" TC
Flange diameter
mm (inch)
25
Internal diameter
mm (inch)
4,7
Connection specification outlet (standard)
Connector
"
1/4" TC
Flange diameter
mm
25
Internal diameter
mm (inch)
4,7 (0.19)
Position of connectors
Inline
Number of flow directions
4
Diameter drive shaft
mm
7
Product wetted materials (standard):
Pump housing
PP
Valve plate
PP
Diaphragms
TPE
Valves
EPDM
O-rings
EPDM
Non-product wetted materials (standard):
Membrane cover
PP
Bearing housing
SS316L
Base plate
SS316
Hood
SS316
Dimensions pump with motor and housing:
Length
mm (inch)
285 (11.22)
Width
mm (inch)
115 (4.53)
Height
mm (inch)
184 (7.24)
Weight pump with motor and housing
kg (lb)
Ca.7 (15.8)
Custom tarif number