User Guide
404 Westridge Dr. Tel (831) 761-6555
Watsonville, CA 95076, USA Fax (831) 761-6544
1-800-525-1609 www.applied-motion.com
2
I/O
• 8 optically isolated digital inputs for S/Q
models,
• 1 analog input, 0 to 5 Volts
• 4 optically isolated digital outputs for S/Q
models
• Please see Applied Motion Products
website or the TSM17S/Q Hardware
Manual for more information.
To Power Supply-
To Power Supply+
To Earth Ground
RC880
TSM
V- V+
V- V+
Vin
-
+
Vout
+
-
Power Supply
4
Congure the Drive
• Install the “Step-Servo Quick Tuner” software application.
• Connect the drive to PC using the programming cable.
• Run the software application.
• Apply power to the drive.
• The software will communicate with the drive and display
the model & rmware version.
• Follow the steps on the “Step-Servo Quick Tuner” to
set up. For Q models, use Step Servo Quick Tuner's "Q
Programming" tab to create and download Q programs.
3
Connect the Power Supply
• Connect the power supply “+” terminal to the drive “+”
terminal & the power supply “-” terminal to the drive “-”
terminal using 16 to 20-gauge wire.
• Be careful not to reverse the wires. Reversing the
connection may open the internal fuse and void the
warranty.
• If a regulated power supply is being used, there may be
a problem with regeneration that can be solved with the
use of an Applied Motion Products RC880 Regeneration
Clamp. Please see the Applied Motion Products website
or the TSM17S/Q Hardware Manual for more information.
1
Requirements
You will need these items to set-up TSM17S/Q:
• a 12 - 48 volt DC power supply
• a small at blade screwdriver for tightening the
connectors (included)
• a PC running Microsoft Windows XP, Vista, or
Windows: 7/8/10/11
• Software: Step-Servo Quick tuner
• a programming cable (included)
TSM17S/Q
Integrated Step Servo Motor
Quick Set-Up Guide
Safety Instructions
• DO NOT
apply power until connections to the drive have been made.
• Only qualied personnel should assemble, install, operate, or maintain this equipment.
• Read all available documentation before assembly and operation.
• It is vital to ensure that all system components are connected to earth ground.
• This product contains electrostatically sensitive components that can be damaged by incorrect
handling.
920-0077B
18645 Madrone Pkwy
Morgan Hill, CA 95037
800-525-1609
applied-motion.com