User Guide
a) Apply power to the drive.
b) Enter the proper IP address (refer to step 1d above), then select the
“Drive” tab and press the “Ping” button. You should receive a response
similar to that shown here.
c) Select the appropriate operating mode for your drive.
d) If using an Applied Motion servomotor, press the “Open” button, navigate
to the SVAC3 folder, and select a tuning le. Select the le that most
closely matches your inertia load. The le names indicate the inertia ratio
for which they were optimized. For example, the le M0200-101-4-X5.svt
was optimized for the M0200-101-4 motor at a 5:1 inertia ratio.
Step 5
a) Select the “Motor - Encoder” tab and conrm settings for motor
maximum current and pole count, as well as the encoder resolution
are correct. If you are using a non-AMP motor, these data must be
obtained from your motor’s datasheet.
b) Execute the Timing Wizard, following the on-screen prompts. This
will ensure that the drive can properly commutate the motor.
Step 6
a) Select the “Tuning - Sampling” tab.
b) If a factory tuning le was used in Step 5, the system is already tuned for the specied load. If us-
ing a third-party motor, the system must be tuned manually. Consult the Quick Tuner™ Software
Manual for step-by-step tuning instructions.
The Quick Tuner™ Software Manual should be considered required reading for anyone tuning a servo
system.
Step 7
Select the “Inputs - Outputs” tab, and congure any dedicated-function I/O your applica-
tion may require.
Step 8
Download your settings to the drive. Your drive is now congured for use.
Step 9
If you have any questions or comments, please call
Applied Motion Products Customer Support:
(800) 525-1609, or visit us online:
applied-motion.com.
18645 Madrone Pkwy
Morgan Hill, CA 95037
Tel: 800-525-1609
applied-motion.com