SHOWER HANDBOOK IMPORTANT This booklet should be given to the customer after installation and demonstration.
Thank you for choosing a quality “Redring” product manufactured in Peterborough, England. Contents User information Page How to use your shower...............................................2 Routine Maintenance....................................................5 How your shower works ...............................................6 Troubleshooting ............................................................6 Additional spares & accessories ................................
To Increase Temperature - Press the warmer button once in the centre (Confirmed with a single bleep). fig 2. The number will change to the new setting. i.e. Display will change from digit 6 to digit 7. Wait for a few seconds for the shower to increase the temperature to the new setting. Repeat this for your ideal setting waiting each time for the temperature to be achieved.
Over Temperature Shutdown If an abnormal condition occurs which causes the water to get too hot. The unit will automatically shutdown straight away and the water will stop flowing, this is to prevent any hot water coming out of the handset. This is indicated by 8 short bleeps and the display flashing a lowercase “o” and then “t” (see fig.6). This will continue until the water is at a safe temperature.
Handset Operation Fig. 10 Surf (Outer spray only) Sport (Inner spray only) Cascade (Combination of inner/outer) There are three defined spray plate settings adjustable by rotating the spray plate (see fig. 10). The modes have a positive click to identify them. The spray head rotates through approximately 130o. In Order To Maintain The Performance Of Your Shower You Must Clean The Shower Head regularly.
How Your Shower Works 1. Water is heated instantaneously as it flows over the heaters in the plastic heat exchanger assembly. 2. The shower automatically adjusts the power to the heating elements and flow of water to achieve the selected water temperature. The electronics senses the incoming water temperature and the flow of water through the heat exchanger. It then works out how many heaters to switch on so that the shower temperature matches the temperature selected by the buttons. 3.
Self Help Check List a) Water too HOT Press the cooler button when in NORMAL operation. Clean spray plate holes. b) Water too COLD Press the warmer button when in NORMAL operation. c) Spray pattern poor Clean spray plate. Select outer / inner only. d) Display behaves erratically Switch off electricity at ceiling / isolating switch, wait a few seconds, switch on again. (Note the shower should be switched off each time after use at the ceiling switch).
Installation Instructions The installation should be done by qualified personnel and checked by the electricity supply authority.
Position the shower so that it is vertical then mark and drill the other two holes. Then fix the shower to the wall. Fig. 12 (rear view) Assemble the accessories as shown in fig 16 (or 17 for style accessories). Fix the riser rail with screws provided. The fixing holes are revealed by removing the plastic fronts. A grab rail is provided with the Selectronic "plus" shower. This is to be mounted according to BS8300: 2001.
The earth continuity conductor of the electrical installation MUST BE effectively connected electrically to all exposed parts of the appliances and services in the room in which the water heater is to be installed in conformity with the current BS 7671 (I.E.E. wiring regulations) Replace the side section along with seal. Fig. 14 Connect flying lead from front cover to PCB. Replace the front cover and fasten in position with three screws. d) Commissioning The unit is supplied in TEMPLOCK mode.
Optional Accessories (standard fittings only) 2 Metre smooth shower hose 2 Metre convoluted shower hose 83-593530 83-792578 1 Metre riser rail 83-593529 Care pack (1 Metre rail / 2 Metre smooth hose) 83-792354 Grab rail 83-593568 Spares Solenoid valve + seals 93-594101 Cable entries (top / bottom) 93-594111 Triac PCB 93-594102 Side section 93-594112 Flow transducer 93-594103 Logic PCB 93-594113 Flow assy + motor (no outlet) 93-594104 Front cover assy complete 93-594114 Valve motor 93-5941
Guarantee We, Applied Energy Products Ltd., guarantee that should any part of this instant water heater prove to be defective by reason of faulty workmanship or material within 36 months (for outside U.K. contact your local distributor) of the date of purchase, we will replace the defective parts FREE OF CHARGE on condition that :(a) The appliance has been correctly installed and used on the supply circuit or voltage printed on the rating plate.