User Guide

10
The second set of 3 mounted directly below are ‘Shower Control Feature Setting Options’ and can be
set to suit the requirements of user. The function and options for each ‘DIP Switch’ are shown below:-
PLEASE NOTE! The Selectronic Premier is
factory set with the ‘DIP Switch’ set as follows:-
1 at ‘0’ (Fixed Flow)
2 at ‘0’ (Preset Start-Up)
3 at ‘0’ (Flow Limited to 6 l/m Max).
DIP 1:- This is used to select “Eco Power
Save”.
Fixed Flow =
With the ‘DIP Switch’ pushed to the
left the shower will save power. As the
temperature is reduced, the shower
will use less power (Eco Power ON).
Maximise Flow =
When the ‘DIP Switch’ is pushed to the
right the shower will use maximum
power at all temperature settings (Eco
Power OFF).
DIP 2:- Preset Start-up =
With the ‘DIP Switch’ pushed to the
left the shower will start up at a preset
temperature every time it is used.
The start up temperature depends on
The setting of the ‘Temp Lock Switch’.
a) When set to 1 the start up = 40°C Nominal (Digit 5 on front cover display)
b) When set to 2 the start up = 41°C Nominal (Digit 6 on front cover display)
c) When set to 3 the start up = 43°C Nominal (Digit 8 on front cover display)
d) When set to 4 the start up = 41°C Nominal (Digit 6 on front cover display)
Previous Setting =
With the ‘DIP Switch’ is pushed to the right the shower will start up at the same temperature
as the last time the shower was used. E.g. If the shower was set to Digit 4 (39°C) when it was
switched off, then it will start up at Digit 4 the next time it is used.
DIP 3:- This is used to select “Eco Water Save”
Flow Limited to 6 l/m max =
When the ‘DIP Switch’ is pushed to the left the shower will prevent high water flow rates.
The shower will not supply water at a flow rate greater than 6 l/m (Eco Water Save ON)
Temperature unaffected. This selection meets the ‘Sustainable Home’ water consumption
requirement per person for showering.
Flow Limited to 9 l/m max =
When the ‘DIP Switch’ is pushed to the right the shower does not restrict the flow rate.
The shower is capable of supplying water at a flow rate greater than 6 l/m ‘DIP Switch’ (Eco
Water Save OFF).
I
I
I
O
N
1
2
3
ON
1
2
3
X
Diagram 9
Position ‘0’
(Switch to the Left)
Position ‘1’
(Switch to the Right)
DIP 1: Flow Optimiser Switch
DIP 2: Start-Up Temperature Setting
DIP 3: Maximum Flow Limiter
Flow Limited to 6 l/m max Flow Limited to 9 l/m max
Fixed Flow
Preset Start-Up
Maximise Flow
Previous Setting
11
Diagram 10
Diagram 11
Diagram 12
Commissioning
Ensure the water and electricity are switched
on to the unit.
Press and hold the Cooler button until
confirmed with one audible short bleep.
See Diagram 10
The digital display will illuminate with a capital
“C”. See Diagram 11
If the button does not respond, ensure that the
flying lead from the PCB has been connected
to the front cover. See Diagram 6
Allow the unit to fill and wait for the water to
come out of the handset then press the
Stop/Start button turning the shower OFF
(Confirm with three audible short bleeps).
See Diagram 12
Re-start - Press Start /Stop Button in the
centre. (Confirmed with a single bleep) See
Diagram 12
Check that the outlet temperature increases to
a comfortable temperature.
Check for leaks.
Press START/STOP button to switch the unit
OFF (Confirm with three audible short
bleeps). See Diagram 12
This completes the commissioning.
1
Audible Short
Bleep
Audible Short
Bleep
1
Audible Short
Bleeps
3
IMPORTANT! This appliance is not intended for use by persons (including
children and the infirm) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their
safety.
Children should be supervised to ensure that they do not play with the appliance.
I
Warning! Do Not Switch The Shower On If You Suspect It Of Being Frozen,
Wait Until You Are SureThat It Has Been Completely Thawed Out.