REDRING ACTIVE 320S SMART TECHNOLOGY ELECTRIC SHOWER Installation and User Guide IMPORTANT: This booklet should be left with the user after installation and demonstration
CONTENTS Section Page Introduction _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 Important Safety Information _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 How to use your Active 320S Shower (Detailed) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 How your Active 320S Shower Works _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 4 How to maintain your Active 320S Shower _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 5 What to do if thin
9. Isolate the mains electrical and water supply before removing the front cover of the appliance. HOW TO USE YOUR ACTIVE 320S SHOWER (DETAILED) 1. Ensure the electricity and water are turned on to the unit. 2. Your shower has 3 power settings selected by turning outer knob “A”. The most popular is “ (high)”. There are also options for a “ or “ (medium)” (cold)” shower (see notes 8 and 9). For this example turn outer knob “A” to “ and set inner knob “B” to “12 o’clock”. (high) ” 3.
WARNING: CONSIDERATION SHOULD BE GIVEN TO SUPERVISING THE YOUNG, ELDERLY AND THE INFIRM WHILST THEY USE THIS SHOWER HOW YOUR ACTIVE 320S SHOWER WORKS 1. Water is heated instantaneously as it flows over the heating elements in the copper cylinder (diagram 2). 2. The heaters are only switched on when sufficient water is flowing. This is done automatically with a switch which works on water pressure and is indicated by the neon light illuminating depending on the power selected by outer knob “A”. 3.
will turn off the power to the heating elements, resulting in a cold shower. This will be indicated by the neon light going out. HOW TO MAINTAIN YOUR ACTIVE 320S SHOWER It is recommended that the shower unit and hose etc. be cleaned using a soft cloth and that the use of abrasive or solvent cleaning fluid be avoided. We recommend that before any cleaning, the isolating switch be turned off, thus avoiding accidentally switching on the shower.
Water continues to flow when “ (stop)” selected This is normal. The shower includes a shutdown feature that means the water will continue to flow for up to 3 seconds after “ (stop)” has been selected. Broken parts Please contact our spares department on 08709 000420 (UK only). Fitting instructions are provided with most spares WHAT TO DO IF THINGS GO WRONG (2) PROFESSIONAL SERVICE If the previous “Self Help” checks fail to restore the performance, you should seek professional help.
The model and serial number are located on the bottom face of the shower. Make a note of those numbers here, and be sure to quote them if you call for advice. Model Number: 53-67_ _ _ _ _ _ _ _ _ _ _ _ _ _ Serial Number: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ HOW TO INSTALL YOUR ACTIVE 320S SHOWER WARNING: ALL WIRING AND INSTALLATION MUST BE SUPERVISED BY A SUITABLY QUALIFIED PERSON.
6. Decide the position of entry of the cold water pipe into the unit. If top, cut away the backplate. If rear, please read the section on plumbing. If bottom, remove the front cover (complete with knobs) and cut away the detachable corner section as shown. 7. If you have not yet done so, remove the front cover assembly by undoing the retaining screws at the top and bottom of the unit and lifting the cover off. Your shower is provided with 2 fixing positions in the backplate (see diagram 4).
7. The shower is designed to have an open outlet and should only be used with ”Redring” recommended fittings. Do not connect the handset until after the shower front cover and corner section are fitted. WARNING: DO NOT FIT A TAP ON THE SHOWER OUTLET. WARNING: TAKE CARE TO AVOID RESTRICTING THE OUTLET OF THE PRESSURE RELIEF DEVICE c) ELECTRICAL WARNING: THIS SHOWER MUST BE EARTHED. The electrical installation must be in accordance with the current BS.
a. b. c. d. e. f. g. 5. Re-Fit the front cover (see diagram 9) Ensure outer knob “A” is aligned fully anti-clockwise to the “ (stop)“ position. Ensure inner knob “B” is aligned to the “ (high)” position. In the main body of the shower, turn the “Drive Spider” fully anti-clockwise until it stops. In the main body of the shower, turn the “Drive Gite” anti-clockwise until it is at “12 o’clock”.
8. DEMONSTRATE OPERATION TO USER ADDITIONAL ACCESSORIES SPARE PARTS Please Note:- The fitting of Spare Parts must be supervised by a suitably qualified person. White 2 metre Shower Hose WRAS Water Isolating Valve Chrome Multi-Mode Accessories Chrome Premium Accessories Chrome Curved Accessories Curtain and Rail Pack Curtain and Rail Pack with Non-Slip Mat Cat Cat Cat Cat Cat Cat No. No. No. No. No. No. 83792578 93792452 83595318 83595319 83595320 83792812 Cat No.
Full details of terms and conditions are available on request from:- APPLIED ENERGY PRODUCTS LIMITED MORLEY WAY, PETERBOROUGH PE2 9JJ TEL: +44 (0) 1733 456789 FAX: +44 (0) 1733 310606 Website: www.redring.co.uk HOW TO USE YOUR ACTIVE 320S SHOWER (SUMMARY) 1. Ensure the electricity and water are turned on to the unit. 2. Turn outer knob “A” clockwise to the “Power Select” position of your choice. The water will flow, and the neon indicator light will glow. = High Power = Medium Power = Cold Shower 3.
• The position of inner knob “B” will be approximately the same each time the shower is used, varying only with incoming water temperature or pressure changes (e.g. you will only need to change from summer to winter). • During normal operation, if an overheated water temperature is sensed then the heater will switch off and the neon indicator will go out. The water will continue to flow and cool down before the heater switches back on again.