Technical information
 2.7.2.3.3 Preliminary Steps
 Proceed as follows.
 1.  Insert the Color Displays Test-Pattern Diskette into drive A of the
     system unit.
     CAUTION:
     Use caution when making adjustments with the cover removed.  There are
     high voltages on the analog and video cards.
 2.  Power on the system unit and the display.  The system unit runs its
     internal checks, and then loads the program from the diskette.
     Note: The following error codes may appear.  Take the action specified
     to clear the problem.
        ASP001E: Cannot open adapter
         The setup program has detected that the display is attached to the
         Personal System/2 planar VGA port.  To continue testing in VGA
         modes only, type VGA at the A: DOS prompt and press Enter
        ASP002E: Cannot open display
         The setup program has detected that a display adapter is installed
         in the system but cannot find a display attached.
         a.  Power off the system unit.
         b.  Check that the display to be tested is attached to the adapter
             nearest slot 1.
         c.  Power on the system unit.
         Alternatively, remove all adapters not needed for the test,
         reconfigure your Personal System/2 and retry the setup test.
 3.  With the Brightness control set to center detent (midpoint), adjust G2
     and Focus until the setup menu is visible.  Select pattern C, and
     depress the keyboard spacebar until black field is selected, then
     adjust the G2 control to give minimum background illumination.
 4.  Allow 20 minutes for the display to warm up before making any further
     adjustments.
 5.  Set the Contrast control to midpoint.
PS/2 Displays Maintenance Manual
Preliminary Steps
¦ Copyright IBM Corp. 1993
2.7.2.3.3 - 1