Technical information

2.6.1.4 Signal Cables
The signal cable is clamped to the card tray.
1. Refer to Figure 9-3.
2. Remove the connector 1 from the analog card.
3. Remove the signal connector 2 from the video card.
4. Remove the ground wire 3 from the video card.
PICTURE 50
Figure 9-3. Removing the Connectors, 9515 Display
5. Refer to Figure 9-4.
6. Remove the four screws 4 to release the analog card.
7. Lift the card at the rear, and ease it away from the retaining lugs
5 on the front of the card tray assembly.
8. Remove the clamp screws 6 at each end of the cable.
Note: Note how each clamp is fitted on the cable before removing the
signal cable from the retention tabs.
PICTURE 51
Figure 9-4. Removing the Analog Card and Cable Clamp Screws, 9515 Display
PICTURE 52
Figure 9-5. Signal Cable Clamps, 9515 Display
Replacement:
1. Ensure that the front clamp makes contact with the braid and the cable
sheath, because it acts as a strain relief for the cable.
2. Replace the cable in the retention tabs so that the longer section of
braid is aligned with the rear clamp. This clamp is attached to the
braid only.
PS/2 Displays Maintenance Manual
Signal Cables
¦ Copyright IBM Corp. 1993