Service manual

06/2010
14. You must run AutoCal to complete the installation. Refer to SM500-15.
15. Check the unit for normal operation per SM500-16 ‘Testing the RV500’
Kit Parts List:
1330 Flowmeter assembly
Figures:
Figure-3 Frontal View of RV500 with Door Removed
Figure-4 View of Electronic Drawer
Model: RV500-F-L / RV501-F-L
SM500-13 Gas Solenoid Replacement
Other service documents required:
SM500-16 Testing the RV500
Tools Required:
Basin wrench or crow foot wrench
Adjustable wrench
1. Turn power OFF, water OFF, and gas OFF.
2. Disconnect the gas supply.
3. Disconnect the four spade connectors at the gas solenoid.
4. Place an adjustable wrench on the modulating valve hex and unscrew the gas solenoid 1073
from the end of the piping and remove from the unit.
5. Remove the flare elbow from the gas solenoid.