Service manual
06/2010
outside of the heat exchanger and the heat exchanger other side is resting on the ledge of the
burner assembly. See figure -8.
6. Be sure the table is level. Place a level on the burner bracket. Adjust the burner assembly until
it is level and mark the heat exchanger through the two mounting holes in the burner bracket.
7. Remove the burner assembly and drill ¼” holes at the two marked holes on the heat exchanger.
8. Again place the burner on the heat exchanger. From the inside of the heat exchanger assemble
the heat exchanger backup plate through the two holes of the heat exchanger and burner. Use
the two new 8-32 self-locking screws 1397 and a 3/8” open end wrench to tighten the assembly.
Recheck that the upside down assembly is still level as determined in step 6.
9. Reverse the procedure of steps 3, and 2 to complete assembly.
10. Check the unit for normal operation per SM500-16 ‘Testing the RV500’
Kit Parts List:
1315 Burner assembly
Figures:
Figure-3 Frontal View of RV500 with Door Removed
Figure-4 View of Electronic Drawer
Figure-8 Heat Exchanger / Burner Assembly Method
Model: RV500-F-L / RV501-F-L
SM500-11 Igniter Replacement
Other service documents required:
SM500-04 Hood Change Procedure
SM500-05 Heat Exchanger / Burner Assembly Replacement
SM500-06 Heat Exchanger Assembly Replacement
SM500-10 Burner Assembly Replacement
SM500-16 Testing the RV500
Tools Required:
Phillips screwdriver
¼” socket
9mm open end wrench
3/8” open end wrench or socket
Level
Pliers
1/8” drill bit
1. Turn power OFF, water OFF, and gas OFF.
2. Remove the hood assembly per SM500-04.