Wiring Diagram
Wire Diagram A15330402 Rev F
FREEZER ICE MAKER INFORMATION
Turn the IM ON and OFF: Press and hold the POWER button for ½ second
to turn the IM ON and OFF. When the IM is ON, the Power button will illumi-
nate solid green
Test Cycling: Press and release the TEST/SERVICE button to start the self-
diagnostic function. The tray will perform 2 rotations. The ice level arm must
be held so that it does not drop during the first rotation (simulating full ice
bin). Once the tray returns to the Home position, the arm can be released.
Allow the arm to drop normally during the second rotation (simulating
empty ice bin). Once the tray returns Home after the second rotation, the
POWER button will change back to solid green if no errors were detected
during the test. This means the IM operates properly. If errors are detected
at any time during the test, the test will stop immediately and the POWER
button will blink rapidly continuously. In this case, there is some internal
failure of the IM. NOTE: If the arm is not held during the first rotation, the
IM will indicate a failure falsely. To run the test again to verify, the IM must
be turned OFF and back ON.
Manual Water Fill: Press and hold the TEST/SERVICE button for 3+ seconds.
Adjust Water Fill Size: Press and hold the POWER and TEST/SERVICE
buttons together for 3 seconds. The POWER button will blink to show the
current setting.
1 blink = small, 2 blinks = med, 3 blinks = large, 4 blinks = extra large. Press
the TEST/SERVICE button to advance to the next level. When at extra
large, the next press goes back to small. The factory default is small.
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair
personnel only. Untrained persons should not attempt to make repairs
due to the possibility of electrical shock. Disconnect power cord before
servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be
returned to their original position and properly secured.
FRESH FOOD ICE MAKER FILL TIME ADJUSTMENT MODE
NOTE: First consider water filter condition before adjusting fill time.
Activate: Press and hold FREEZE BOOST and Ice Maker buttons for
10 secs. Adjustments can be made with the -/+ buttons. The setting
will time out after another 10 secs.
Deactivate: Resets to Normal Operation after 10 secs
Setting # Pressure Condition
Fill Time
1
Normal-High
(more than 60 psi)
3.9 secs
2
Low
(between 30 and 60 psi)
4.6 secs
3
Very Low
(between 20 and 30 psi)
5.8 secs
4
Extremely Low
(less than 20 psi)
7.5 secs
FREEZER ICE MAKER SPECIFICATIONS
Electrical 115 vac (127 vac max) 60 Hertz
FREEZER ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number Wire Color Connects to:
1 Light Blue Neutral
2 Yellow Water Valve
3 Black Line