Cut Sheet

Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Mercmaster
III Low Profile Compact Fluorescent Luminaires
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
V CSA Certification Only.
Lighting
Lighting: EncLosEd and gaskEtEd — arEa — FLuorEscEnt
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© January 2011
1056
Illustrated Features
Ballast Assembly
Utilizingnon-sparkingcomponents
avoidingtheignitionofgasesorvapors
thatmaybepresent(nA).
Hood/Ballast Gasket
Siliconerubbergasketsealsoutmoisture,
dirtanddust.Staysflexible,withstands
hightemperatures.Closuredesign
assuresuniformgasketcompression.
Electrical Protection
Groundwireprovidedtobondmounting
hoodtoballasthousing.
Vented Reflectors
Reflectorsarethick,toughfiberglass-
reinforcedwhitepolyester,ventedfor
cooleroperation.Quicklyattachwith
furnishedstainlesssteelscrews.
Globe Chamber
Completelysealedfromtheballast
housingandoutsidevapors/air(nAnR).
Epoxy Finish
Ballasthousing,hoodsandguardsare
copperfreealuminumwithepoxypowder
coatfinish.
Photocell
Installsthroughknock-outinmounting
hoodsexceptconeandceilingmount.
Providescontinuouson-offdusk-to-
dawncontrol.Notforuseinhazardous
(classified)areas.Hazardouslocation
ratedphotocellsalsoavailable.See
Accessoriespage.
Terminal Blocks (Zone 2)
Aseven-pointterminalblockisprovided
tofacilitatewiring.Terminalblock
accommodateswiresizerangingfrom#8
to#24AWG.
Stainless Steel Inserts
Ballastbodieshavestainlesssteel
threadedinsertstoreceivestainlesssteel
screwsforreflectorsandguard.Prevents
"freezing”,allowingguardsandreflectors
tobeeasilyremovedandreplacedatany
time,withoutdamagetothehousing.
Cooler Operating Cone Hood
Largerslopedsurfaceshedsdusts,dirt
andcombustiblefibersprovidingbetter
heatdissipation.
Prismatic Glass Globes and Refractors
Heat-resistantglobesandglassrefractors
andpolymericrefractorsthreaddirectly
intoballasthousingandsealagainsta
hightemperaturesiliconerubbergasket.
(Polymericrefractorsarenotlistedfor
Zone2areas.)
Fuses
Twoscrewssecurefusekittomounting
bossinanyMercmastermountinghood.
Fuseincluded.
Stainless Steel Latch Assembly
Captive,stainlesssteellatchassembly
boltandnutclosessecurely,resistsattack
ofcorrosiveatmospheres.Swing-away
designsimplifiesservicing.
"Safety" High
Hinge
Extra-highhinge
providesadditional
protectionagainst
accidental
ballasthousing
disengagement
duringinstallation
ormaintenance.