Cut Sheet
Table Of Contents
- Mercmaster™ III Low Profile Compact Fluorescent Luminaires
- Illustrated Features
- Family Tree
- Catalog Numbering Guide
- Thermal Performance
- Pendant — One Hub (Rigid or Flexible Mounting)
- Ceiling — Five Hubs, Four Close-Up Plugs
- 25° Stanchion
- Ballast Bodies
- Mounting Hoods
- Accessories
- Electrical Specifications
- Dimensions
Line Voltage Type of Ballast Starting and Operating Amps Total Watts
26 Watt PL-T Fluorescent
120 Electronic .250 28
277 Electronic .110 28
347 Electronic .080 27
32 Watt PL-T Fluorescent
120 Electronic .300 36
277 Electronic .130 36
347 Electronic .150 36
42 Watt PL-T Fluorescent
120 Electronic .410 48
277 Electronic .180 48
347 Electronic .140 43
52 Watt PL-T Fluorescent
120 Electronic .460 56
277 Electronic .220 56
347 Electronic .170 54
57 Watt PL-T Fluorescent V
120 Electronic .480 58
277 Electronic .210 57
347 Electronic .180 61
64 Watt PL-T Fluorescent
120 Electronic .580 69
277 Electronic .260 69
347 Electronic .190 66
84 Watt PL-T Fluorescent
120 Electronic .760 91
277 Electronic .320 91
347 Electronic .280 86
114 Watt PL-T Fluorescent V
120 Electronic .960 116
277 Electronic .420 114
347 Electronic .360 122
Fuse catalog number: MLF2 (1 required for 120 V or 277 V) – 2-Amp fuse, time delay.
Minimum starting temperature: 0 °F/-18 °C
Energy Efficiency and Lamp Life Comparison Lumen Output Comparison
Lamp Type Watts Lumens
Rated Average
Life (Hours) Light Output as Function of Temperature
Incandescent 100 1750 750
Degrees F
Relative
Light
Output %
PL-T
(Amalgam)
Quad ---
Incandescent 150 2880 750
Incandescent 200(PS-25,PS-30) 3710 750
Incandescent 200(A-23) 4010 750
PL-TFluorescent 26 1800 10,000
PL-TFluorescent 32 2400 10,000
PL-TFluorescent 42 3200 10,000
PL-TFluorescent 52 3600 10,000
PL-TFluorescent 57V 4300 12,000
PL-TFluorescent 64 4800 10,000
PL-TFluorescent 84 6400 10,000
PL-TFluorescent 114V 8600 12,000
Highlumenoutputoftheamalgamtechnologylampvs.the
reducedlightoutputatvariabletemperaturesfromatypical
compactfluorescentlamp.
V CSA Certification only.
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx nA nR IIC (Z2)
Class I, Zone 2, Ex nR IIC (Z) V
Class II, Division 1 and 2, Groups E, F, G
Class III
Simultaneous Exposure (Class I, Division 2/
Class II, Division 1)
Fixtures Outside Type (Salt Water)
Type 4X
IP66
Lighting
Lighting: EncLosEd and gaskEtEd — arEa — FLuorEscEnt
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© January 2011
1065
Mercmaster
™
III Low Profile Compact Fluorescent Luminaire Electrical Specifications
Enclosed and Gasketed. For Hazardous and Wet Locations
Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors.