Cut Sheet
* Photometric data is based on a xture with
a 175-watt clear Pulse Start Metal Halide
lamp (14,000 lumen), without guard. For
candlepower values of xtures with other
PSMH lamps, use the following multipliers:
for a 100 W (8,500 lumen) PSMH lamp – 0.607;
for a 70 W (5,000 lumen) PSMH lamp – 0.357.
For candlepower values of xture with guard,
multiply by – 0.95.
Code•Master Jr.
™
HID Factory Sealed Luminaire PSMH Photometric Data
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
Zone Lumens Total Luminaire Efficiency = 77.8%
REPORT NUMBER: CJP17G
Lamps: 175 W Pulse Start Metal Halide with Globe only *
0-10 46.64 CIE Type - General Diffuse
10-20 176.99
20-30 380.01
30-40 480.30 Coefficients of Utilization - Zonal Cavity Method
40-50 1042.35 Effective Floor Cavity Reflectance 0.20
50-60 1252.88 % Ceiling Rcc 80 70 50 30 10 0
60-70 1378.40 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 1611.81 Zonal Lumen Summary 0 85 85 85 85 79 79 79 79 69 69 69 59 59 59 51 51 51 46
80-90 1741.68 Zone Lumens % Lamp % Fixture 1 73 67 62 58 67 62 58 54 53 49 46 45 42 39 37 35 33 29
90-100 1758.28 0-30 603.64 3.4 4.4 2 64 56 49 43 59 52 45 40 44 39 35 36 32 29 30 27 24 20
100-110 1643.71 0-40 1083.94 6.2 8.0 3 57 48 40 34 53 44 37 31 37 31 27 31 26 22 25 21 18 15
110-120 1371.76 0-60 3379.18 19.3 24.8 4 52 41 33 27 48 38 31 25 32 26 22 26 22 18 21 17 14 12
120-130 694.24 0-90 8111.07 46.3 59.6 5 47 36 28 22 43 33 26 21 28 22 18 23 18 15 19 15 12 9
130-140 27.13 90-120 4773.75 27.3 35.1 6 43 32 24 19 40 29 23 18 25 19 15 20 16 12 16 13 10 7
140-150 3.14 90-130 5467.99 31.2 40.2 7 40 28 21 16 36 26 20 15 22 17 13 18 14 10 15 11 8 6
150-160 0.67 90-150 5498.26 31.4 40.2 8 37 26 19 14 34 24 17 13 20 15 11 17 12 9 13 10 7 5
160-170 0.08 90-180 5499.05 31.4 40.4 9 34 23 17 12 31 21 15 11 18 13 9 15 11 8 12 9 6 4
170-180 0.03 180-0 13610.12 77.8 100.0 10 32 21 15 11 29 20 14 10 17 12 8 14 10 7 11 8 5 4
Zone Lumens Total Luminaire Efficiency = 66.4%
REPORT NUMBER: CJP17ST
Lamps: 175 W Pulse Start Metal Halide with
Standard Dome Reflector *
0-10 281.17 CIE Type - Direct
10-20 914.71
Plane
Spacing
Criteria
20-30 1567.70
30-40 1691.30 0-180 1.42 Coefficients of Utilization - Zonal Cavity Method
40-50 2211.91 90-270 1.42 Effective Floor Cavity Reflectance 0.20
50-60 2339.53 Diagonal 1.76 % Ceiling Rcc 80 70 50 30 10 0
60-70 1900.87 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 568.93 Zonal Lumen Summary 0 79 79 79 79 77 77 77 77 74 74 74 71 71 71 68 68 68 66
80-90 145.98 Zone Lumens % Lamp % Fixture 1 72 69 66 64 70 67 65 63 65 63 61 62 60 59 60 58 57 56
90-100 1.23 0-30 2763.57 15.8 23.8 2 65 60 55 51 64 58 54 51 56 52 49 54 51 48 52 49 47 46
100-110 0.00 0-40 4454.87 25.5 38.3 3 59 52 46 42 57 51 46 41 49 44 41 47 43 40 45 42 39 38
110-120 0.00 0-60 9006.31 51.5 77.5 4 54 46 39 35 52 45 39 35 43 38 34 41 37 34 40 36 33 32
120-130 0.00 0-90 11622.09 66.4 100.0 5 49 40 34 29 48 40 34 29 38 33 29 37 32 29 35 31 28 27
130-140 0.00 90-120 1.23 0.0 0.0 6 45 36 30 25 44 35 29 25 34 29 25 33 28 25 32 28 24 23
140-150 0.00 90-130 1.23 0.0 0.0 7 42 32 26 22 41 32 26 22 31 26 22 30 25 22 29 25 21 20
150-160 0.00 90-150 1.23 0.0 0.0 8 39 29 23 19 38 29 23 19 28 23 19 27 22 19 26 22 19 18
160-170 0.00 90-180 1.23 0.0 0.0 9 36 27 21 17 35 26 21 17 26 21 17 25 20 17 24 20 17 16
170-180 0.00 180-0 11623.32 66.4 100.0 10 34 25 19 16 33 24 19 16 24 19 15 23 18 15 22 18 15 14
Zone Lumens Total Luminaire Efficiency = 63.2%
REPORT NUMBER: CJP17AN
Lamps: 175 W Pulse Start Metal Halide with
30° Angle Dome Reflector *
0-10 238.28 CIE Type - Direct
10-20 739.68
Plane
Spacing
Criteria20-30 1242.92
30-40 1491.36 0-180 2.10 Coefficients of Utilization - Zonal Cavity Method
40-50 1770.34 90-270 1.60 Effective Floor Cavity Reflectance 0.20
50-60 1739.56 Diagonal 1.62 % Ceiling Rcc 80 70 50 30 10 0
60-70 1484.79 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
70-80 1197.57 Zonal Lumen Summary 0 75 75 75 75 73 73 73 73 69 69 69 65 65 65 62 62 62 61
80-90 689.02 Zone Lumens % Lamp % Fixture 1 66 63 59 56 64 61 58 55 58 55 53 55 53 51 52 50 49 47
90-100 254.20 0-30 2220.87 12.7 20.1 2 60 53 48 44 58 52 47 43 49 45 42 47 43 41 44 42 39 38
100-110 105.48 0-40 3712.23 21.2 33.6 3 54 46 40 36 52 45 40 35 43 38 34 41 37 33 39 35 32 31
110-120 35.72 0-60 7222.13 41.3 65.3 4 49 41 34 30 47 39 34 29 38 33 29 36 31 28 34 30 27 26
120-130 41.95 0-90 10593.52 60.5 95.8 5 45 36 30 25 43 35 29 25 33 28 24 32 27 24 30 26 23 22
130-140 8.72 90-120 395.41 2.3 3.6 6 41 32 26 22 40 31 26 21 30 25 21 29 24 21 27 23 20 19
140-150 6.06 90-130 437.36 2.5 4.0 7 38 29 23 19 37 28 23 19 27 22 18 26 21 18 25 21 18 16
150-160 4.53 90-150 452.13 2.6 4.0 8 35 26 21 17 34 26 20 17 25 20 16 24 19 16 23 19 16 14
160-170 2.20 90-180 459.54 2.6 4.2 9 33 24 19 15 32 24 18 15 23 18 15 22 17 14 21 17 14 13
170-180 0.68 180-0 11053.05 63.2 100.0 10 31 22 17 13 30 22 17 13 21 16 13 20 16 13 19 15 13 12
Lighting
Lighting: ExpLosionproof — ArEA — hiD
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1215