Cut Sheet
Code•Master Jr.
™
HID Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 50 W, 70 W, 100 W, 150 W HPS; 50 W, 70 W, 100 W, 175 W PSMH. 175 W MH V. Medium Base. For Use with Threaded Metal Conduit.
“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.
Range
(°F)
664-
842
619-
662
574-
617
538-
572
502-
536
448-
500
421-
446
394-
419
358-
392
331-
356
322-
329
277-
320
250-
275
214-
248
187-
212
185
Temp.
Range
(°C)
351-
450
326-
350
301-
325
281-
300
261-
280
231-
260
216-
230
201-
215
181-
200
166-
180
161-
165
136-
160
121-
135
101-
120
86-
100
85
Lamp
Watts
Ballast
Type
†
104 °F/40˚ °C ➊ 131 °F/55 ˚°C ➊ 149 °F/65 °C ➊ 104 °F/40 ˚°C ➋
Ambient
Temp. “T”
Numbers
Supply
Wire Temp
°F/°C
Ambient
Temp. “T”
Numbers
Supply
Wire Temp
°F/°C
Ambient
Temp. “T”
Numbers
Supply
Wire Temp
°F/°C
Ambient
Temp. “T”
Numbers
Supply
Wire Temp
°F/°C
High Pressure Sodium — Medium Base Lamps
50 MT,TT T6 167/75 T5 167/75 T4A 167/75 T4 167/75
70 MT,TT,480V T5 167/75 T4A 167/75 T4A 167/75 T4 194/90
100 MT,TT,480V T4A 167/75 T4 194/90 — T3B 194/90
150 MT,TT,480V T3C 167/75 — — —
Pulse Start Metal Halide — Medium Base Lamps
50 MT,TT T6 167/75 T5 167/75 T4A 194/90 T3C 194/90
70 MT,TT,480V T5 167/75 T4A 167/75 T4A 194/90 T3C 194/90
100 MT,TT,480V T4A 194/90 T4A 194/90 —
175 MT,TT,480V T3B 194/90 — — —
Metal Halide — Medium Base Lamps V
175 MT,TT,480V T3B 185/85 — — —
Fixture and Accessory Weights lbs/kgs
Fixture Size Fixture Weight Reflector Weight Guard Weight
35Wthru175W 28-32/12.70-14.51 3/1.36 1/0.45
Mounting Hood Weights lbs/kgs
Pendant Ceiling Bracket Stanchion
2/.91 4/1.81 6/2.72 2/0.91
NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
Electrical Code and the Canadian Electrical Code.
† MT is Multi-Tap for 120/208/240/277 V, TT is Tri-Tap for 120/277/347 V.
➊ Class I, Division 1 Locations.
➋ Class II, Division 1 Locations.
V CSA Certification only.
NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Marine type electric xtures, outside type
(salt water)
CSA: V
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
Type 4X
Exd IIB + H
2
Lighting
Lighting: ExpLosionproof — ArEA — hiD
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© September 2010
1206