Cut Sheet
“T” Numbers Represent the Maximum Surface Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number
T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp
Range
(°F)
664-
842
619-
662
574-
617
538-
572
502-
536
448-
500
421-
446
394-
419
358-
392
331-
356
322-
329
277-
320
250-
275
214-
248
187-
212
185
Temp.
Range
(°˚C)
351-
450
326-
350
301-
325
281-
300
261-
280
231-
260
216-
230
201-
215
181-
200
166-
180
161-
165
136-
160
121-
135
101-
120
86-100 85
Fixtures are for use with Group B atmospheres only when used with Group B mounting hoods. For 26 W,32 W, and 42 W fixtures only.
V CSA Certification only.
† Available in Codemmaster 2 Only
Classified Area Suitability of Code•Master™ Series PLT Fixtures — Suitability includes use of reflector
Class I, Division 1 & 2 with Globe or
with Globe & Reflector
UL/NEC Temp. Ident. No.
Class II, Division 1 & 2 with Globe or
with Globe & Reflector
UL/NEC Temp. Ident. No.
Lamp
Type
Lamp
Watts
Supply
Wire
°F/°C
Ambient
Temp
°F/°C
Nameplate
Marking
Groups
Nameplate
Marking
Groups
PLT
(4-pin)
26 167/75 104/40 T6
B◆,C,D
T4A E,F,G
PLT
(4-pin)
32 167/75 104/40 T6
B◆,C,D
T4A E,F,G
PLT
(4-pin)
42 167/75 104/40 T6
B◆,C,D
T4A E,F,G
PLT
(4-pin)
52
(2x26)
167/75 104/40 T6 C,D T4 E,F,G
167/75 131/55 T5 C,D — —
167/75 149/65 T5 C,D — —
PLT
(4-pin)
64
(2x32)
167/75 104/40 T6 C,D T4 E,F,G
167/75 131/55 T5 C,D — —
167/75 149/65 T5 C,D — —
PLT
(4-pin)
84
(2x42)
167/75 104/40 T6 C,D T4 E,F,G
167/75 131/55 T5 C,D — —
167/75 149/65 T5 C,D — —
Catalog Numbering Guide
CJ F P 26 75 G BU L
Series:
CJ-Code•Master
Jr.
◆
C-Code•Master2
Mouning:
P-Pendant
C-Ceiling
B-Bracket
S-Stanchion
PB-GroupBPendant
◆
SB-GroupBStanchion
◆
HubSize:
75-3/4”
10-1”
150-1-1/2”or1-1/4”
Voltage:
BU-120-277V50/60Hz
A5-347V60HzV
LampType:
F-Fluorescent
Wattage:
26-26Watts
32-32Watts
42-42Watts
52-52Watts
†
64-64Watts†
84-84Watts†
Guard:
G-Guardprovided
Blank-Guardnotprovided
Options:
L-LampsProvided
F-Fused
Z-Zone1
ExdIIB+H
2
V
Code•Master
™
PLT Factory Sealed Luminaires
Explosionproof, Dust-Ignitionproof
Integrally Ballasted. 26 W, 32 W, 42 W, 52 W, 64 W, 84 W Compact Fluorescent. For use with Threaded Metal Conduit.
NEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1 and 2, Groups E, F, G
Class III
NEMA 4X
Suitable for use in wet locations
CEC: V
Class I, Division 1 and 2, Groups B, C, D
Class I, Zone 1 and 2, Groups IIB + H
2
T6
Class II, Division 1 and 2, Groups E, F, G
Class III
CSA 4X
Exd IIB + H
2
Suitable for use in wet locations
Lighting
Lighting: ExpLosionproof — ArEA — fLuorEscEnt
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© January 2011
1241