User Guide
Chapter 8 Solving SAN Problems 111
If You’re Unable to Add a Storage Pool
There are some reserved names you can’t use to name a storage pool. If you enter one
of these names, the OK button in the storage pool sheet is disabled.
If Fibre Channel Performance Is Poorer Than Expected
Mismatched optical transceivers (GBICs) can cause Fibre Channel communication errors
and degrade SAN performance. To ensure good performance, use identical transceivers
(same manufacturer and model number) on both ends of your Fibre Channel cables.
Reserved storage pool names
Affinity InodeExpandInc Rtios
AllocationStrategy InodeExpandMax RtiosReserve
AttrTokenSize InodeExpandMin Rtmb
Brls IoHangLimitSecs RtmbReserve
BrlTime Journal RtTokenTimeout
BufferCacheSize JournalIcBufNum Sectors
BufferPoolSize JournalIcBufSize SectorSize
BWMFields JournalSize Static
DataMigration Log StaticInodes
DataMigrationThreadPoolSize MaxConnections Status
Debug MaxLogs Sticky
DeviceName MaxLogSize StripeBreadth
DirCacheSize MaxMBPerClientReserve StripeClusters
DirFDCacheSize Mbufs StripeGroup
DirWarp MbufSize ThreadPoolSize
Disabled MetaData Type
Disk MirrorGroup UnixFabricationOnWindows
DiskType MirrorReadMethod UnixNobodyUidOnWindows
Enabled MultiPathMethod UnixNobodyGidOnWindows
Exclusive No UnixFileCreationMode …
ForcePerfectFit Node UnixDirectoryCreation …
ForceStripeAlignment OpHangLimitSecs WindowSecurity
FSBlockSize Quotas Write
GlobalSuperUser Read Yes
InodeCacheSize Regular
InodeDeleteMax Rotate