Basics Special Servicing Considerations - 15
X-Y Calibration
After replacing the logic board or mechanical assembly on a
Color StyleWriter 6500, you
must
use the Color SW 6500
X-Y Calibration utility to set factory default carriage values
in printer memory. The Color SW 6500 X-Y Calibration
utility is on the Companion CD (path: Diagnostic Utilities/
Color SW 6500 Utilities).
Refer to Additional Procedures for more information.
Capping Unit
If a Color StyleWriter 6500 printer is brought in for
service, and the customer has had the printer for awhile,
replace the purge unit (922-2912) which contains the
capping assembly.