User`s guide

To check Windows Ports control panel settings:
1 Open the Windows Ports control panel.
2 Select COM3 or COM4.
Repeat this process for both COM ports.
3 Click the Settings button.
4 In the dialog box that appears, click the Advanced button.
5 In the Advanced Settings dialog box, make sure the settings are:
m COM1 3F8 IRQ4
m COM2 2F8 IRQ3
m COM3 3E8 IRQ4
m COM4 2E8 IRQ3
6 Click OK.
If you changed the settings, you must restart Windows for the new settings to
take effect. When you click OK, a message lets you choose to restart now or
delay the restart.
If you are using several serial devices with your computer, make sure that the
line IRQSharing=ON exists in the [386enh] section of the SYSTEM.INI file.
Images are fuzzy, blurry, or blotchy
m The lens may be dirty. Clean the lens. (See “Caring for Your Camera,
earlier in this chapter.)
m The subject or the camera may have moved. Hold the camera steady, and
use the flash. (See “Capturing Images” and “Flash Settings” in Chapter 2.)
m The subject may be out of focal range. Unless you are using the closeup
lens, keep a distance of at least 4 feet between you and the subject. The
flash illuminates subjects between 4 and 9 feet from the camera. Use the
closeup lens to photograph subjects that are between 10 and 14 inches from
the camera.
m The image quality setting may not be appropriate for the subject. Change
to high quality. (See “Image Quality Settings” in Chapter 2.)
52
Chapter 5