Checking that the SCSI chain is properly terminated
To ensure accurate transmission of information, a chain of SCSI devices must
have a terminator at each end. Terminators are built into some SCSI devices
and can also be added externally.
m Your PowerBooks internal hard disk, which is the first device in the chain,
has a built-in terminator. However, you should also add external
terminators as described in these instructions.
m External SCSI devices from Apple do not have built-in terminators.
m External SCSI devices from other vendors may have built-in terminators;
see the documentation that came with the device.
If you are attaching one SCSI device
Make sure that there is
m an external terminator between the system cable and the SCSI device
and
m a terminator (internal or external) on the SCSI device.
If you are attaching more than one SCSI device
Make sure that there is
m a terminator (internal or external) on the last SCSI device; and
m no other terminators (internal or external) or other external devices in the
chain.
If you have too many devices with internal terminators, your Apple-
authorized service provider can remove extra terminators.
Chain configurations are shown in the illustration in step 6 of the following
section.
SCSI terminator
90
Chapter 8