Adjustments
Power Supply Voltage
-
5
6
While maintaining the
voltmeter probe
connections, use a
plastic screwdriver to
adjust VR951 until the
voltmeter reads 50 VDC
± 0.2V.
VR951
Positive Probe at J5
1
...
...
97
98
99
100