All button: Resets all envelopes and the EQ to default values.
Volume Env button: Displays the volume envelope in the foreground of the main display.
The other envelope curves are shown as transparencies in the background. See Working
with Space Designers Volume Envelope.
Filter Env button: Displays the filter envelope in the foreground of the main display.
The other envelope curves are shown as transparencies in the background. See Working
with Space Designers Filter.
Density Env button: Displays the density envelope in the foreground of the main display.
The other envelope curves are shown as transparencies in the background. See Working
in Space Designers Synthesized IR Mode.
EQ button: Displays the four-band parametric EQ in the main display. See Working with
Space Designers EQ.
Reverse button: Reverses the impulse response and envelopes. When the impulse
response is reversed, you are effectively using the tail rather than the front end of the
sample. You may need to change the Pre-Dly and other parameter values when
reversing.
Zooming and Navigating Space Designers Envelope View
When displaying envelopes, the main display offers the following zoom and navigation
parameters (not shown in EQ view).
Overview display
Overview display: Indicates which portion of the impulse response file is currently visible
in the main display, helping you to orientate yourself when zooming.
“Zoom to Fit” button: Click to display the entire impulse response waveform in the main
display. Any envelope length changes are automatically reflected.
A and D buttons: Click to limit the “Zoom to Fit” function to the attack and decay portions
of the currently selected envelope shown in the main display. The A and D buttons are
available only when you are viewing the volume and filter envelopes.