10.6

Table Of Contents
33Control Surfaces Support Guide
Mackie Control utilities buttons in Logic Pro
The four utilities buttons activate the Save, Undo, Cancel, and Enter commands in
Logic Pro.
Utilities buttons
SAVE button: Press to save the current project file. The first time you save a project, a
Save dialog appears on your computer screen. Enter a name and location for the file,
then click the Save button in the dialog.
The main LCD displays this message: “There is a file select dialog on the screen.” The
Position/Time display shows “ALERT.” All LEDs are unlit. Once the Save operation has
been confirmed in Logic Pro, the Mackie Control returns all controls to their previous
state (before you pressed the SAVE button).
Once you have named a project and saved it, further presses of the SAVE button store
the current project state without presenting a Save dialog onscreen or showing any
alerts on the LCD. This allows you to quickly save incremental changes you make as
your project develops.
The SAVE LED is illuminated as soon as you make (savable) changes to your project.
Holding down the OPTION button while pressing SAVE opens the Save As dialog on the
computer screen. This allows you to rename a project or save it in a different location.
UNDO button: Press to undo the last undoable action. Because Logic Pro supports
a nearly unlimited number of undo/redo steps, the green UNDO LED illuminates to
indicate that Redo is available, not to indicate an undoable step. The LCD provides a
warning that performing a reversible editing step will render all Redo steps unavailable.
Hold down the SHIFT button while pressing UNDO to perform a Redo.
Hold down the OPTION button while pressing UNDO to open the Undo History
window.
CANCEL button: Press to cancel or exit an alert that appears on your computer screen.
Pressing the CANCEL button when no alert is visible onscreen does the following:
It opens the Toolbox at the current pointer position.
Alternatively, it performs any function currently assigned to the computer keyboard’s
Esc (Escape) key.
If the Mackie Control currently shows the contents of a folder track, pressing the
CANCEL button exits the folder.
The CANCEL button also lets you invalidate a (blinking) parameter value preselection.
ENTER button: Press to activate the default button in an onscreen alert.
If there is no alert onscreen, and the selected track is a folder track, pressing the
ENTER button opens the folder.